Portable/Benchtop

METCAL 40
  • Advanced – Micro-controller based Technology
  • Heavy Duty Portable / Bench-top Model
  • High Accuracy, Resolution & Stability
  • Large Graphic Display (Multi-information Display)
  • Measurement Capability for TC, RTD, mV / mA / V & Resistance Signals
  • Touch Membrane Keypad
  • Switch Test Contact Measurement
  • Multi-hole Thermowell Inserts
  • Computer Interface & Calibration Software
  • Count down timer (Shows when unit is stable)
  • Stability Indicator
  • Precision Dry Block Calibrator with Multihole Interchangeable Thermowells
  • Ideal for quick / fast Site Calibration of RTDs / TCs / Bi-Metal Thermometers, Temperature Switches / Indicators etc. in Industrial & Marine Application
  • Measuring Accuracy: ±0.025% of rdg.
  • High Accuracy, Resolution & Stability with Measurement Capability for mV / V / mA, Resistance TC (ISA Types : J, K, R, S, N, B, T), RTD (Pt100, Pt200, Pt500, Pt1000 : IEC Standard) Signals
  • Range: 10°C to 120°C
  • Resolution: 0.01°C
  • Accuracy: ±0.2°C
  • Stability: ±0.02°C
  • Stabilisation Time: 7 Minutes
  • Temperature Readout: °C / °F Selectable
  • Axial Uniformity (40 mm): ±0.2°C
  • Radial Uniformity: ±0.02°C
  • Well Diameter: 30 mm
  • Immersion depth: 150 mm
  • Heating Time (Amb. to 120°C): 10 Minutes approx.
  • Cooling Time (Amb. to -10°C): 15 Minutes approx.
  • Cooling Time (120 to -10°C): 25 Minutes approx.
  • Switch Test facility: Provided
  • Interchangeable Thermowells: Multihole to suit 2 x ¼” & 1 x ½” Probes. Other Sizes available as optional
  • Housing: Bench-top
  • Power Supply: 110V AC to 240V AC, 50 to 60 Hz
  • Instrument Dimensions (L x D x H): 160 x 365 x 450 mm
  • Instrument Weight (approx.): 9 Kg.
  • Measurement Capability Thermocouples: ISA Types J, K, R, S, N, B, T; RTD : Pt100, Pt200, Pt500, Pt1000; mA : 0 to 25 mA; mV : 0 to 100 / 1000 mV; Volt : 0 to 10 V; Resistance : 0 to 500Ω / 3.5 KΩ
Measurement: Range, Resolution & Accuracy
Type Range Resolution Accuracy Type Range Resolution Accuracy
mV (Low) 0 to 100 0.01 ±0.05% F.S. TC Type J -100 to 1200 0.1 ±0.1% F.S.
mV (High) 0 to 1000 0.1 ±0.05% F.S. TC Type K -60 to 1260 0.1 ±0.1% F.S.
Volts 0 to 10 0.001 ±0.05% F.S. TC Type R 150 to 1700 0.1 ±0.1% F.S.
mA 0 to 25 0.001 ±0.05% F.S. TC Type S 170 to 1700 0.1 ±0.1% F.S.
Ohms 0 to 500 0.01 ±0.05% F.S. TC Type N 0 to 1300 0.1 ±0.1% F.S.
KOhms 0 to 3.5 0.0001 ±0.05% F.S. TC Type B 920 to 1820 0.1 ±(0.025%+0.2°C)
RTD Pt100 -100 to 800 0.1 ±0.05% F.S. TC Type T 0 to 400 0.1 ±(0.025%+0.1°C)
RTD Pt200 -100 to 600 0.1 ±0.05% F.S.
RTD Pt500 -100 to 530 0.1 ±0.05% F.S.
RTD Pt1000 -100 to 650 0.1 ±0.05% F.S.
  • Basic Instrument
  • Test Leads, Mains Cable & Spare Fuses
  • Multihole Insertion Tubes (to suit 2 x ¼“ & 1 x ½“ probes)
  • Tool for Insertion Tubes
  • Computer Interface & “METCAL” Calibration Software
  • Calibration Certificates are issued in Accordance with our Scope as granted by NABL per ISO/IEC 17025:2017 Standards