Portable/Handheld
Nagman® 25
- Compact, Light Weight Unit with Holster
- Capability to Measure & Simulate DC Voltages, DC Current, Frequency, Resistance, Thermocouples & RTDs
- 5 digits display of Measurement & 6 digits display for Simulation
- Dual LCD with white LED for backlight
- Capability to perform Switch Test & Continuity Test
- Measurement & Simulation of :
- DC Voltages : 50 mV & 500 mV & 5 V in Measurement Mode 100 mV, 1V & 10V in Simulation Mode
- DC Current : 50 mA in Measurement Mode; 20 mA in Simulation Mode
- Resistance : 500 Ω & 5 KΩ in Measurement Mode; 400 Ω, 4 KΩ & 40 KΩ in Simulation Mode
- Thermocouples : R, S, B, E, K, J, T & N
- RTDs : Pt100, Pt1000 & Cu50
- Frequency : 500 Hz, 5 KHz & 50 KHz in Measurement Mode; 100 Hz, 1 KHz, 10 KHz & 100 KHz in Simulation Mode
Input Functions (Measurement)
Functions | Reference | Ranges | Resolution | Accuracy | Remarks |
DC Voltage | 50 mV | -5 to 55 mV | 1 mV | 0.02 + 0.02 | Input Resistance : 100MΩ |
500 mV | -50 to 550 mV | 10 mV | 0.02 + 0.01 | ||
5 V | -0.5 to 5.5 V | 0.1 mV | 0.02 + 0.01 | Input Resistance : 1 MΩ | |
50 V | -5 to 55 V | 1 mV | 0.03 + 0.01 | ||
DC Current (mA) | 50 mA | -5 to 55 mA | 1 mV | 0.02% + 0.01 | Shunt Resistance : 10Ω |
Resistance (Ohm) | 500Ω Test current : approx. 1 mA | 0 to 550 Ω | 0.01 Ω | 0.05% + 0.02 | Open circuit voltage about 2.5 V Does not include lead resistance |
5 KΩ test current; approx. 0.1mA | 0 to 5.50 KΩ | 0.1 Ω | 0.05% + 0.02 Ω | ||
Frequency | 500 Hz | 3 Hz to 500 Hz | 0.01 Hz | ±2 digit | Input Impedance 100KΩ atleast; Sensitivity : 3Vp-p minimum; duty cycle : 50% |
5 KHz | 3 Hz to 5 KHz | 0.1 Hz | |||
50 KHz | 3 Hz to 50 KHz | 1 Hz | |||
Thermocouples | R | 0 to 1767°C | 1°C | 0 to 500°C : 1.8°C | By using ITS-90 temperature scale, the Accuracy does not include the error of internal temperature compensation caused by a sensor. |
S | 0 to 1767°C | 500 to 1767°C : 1.5°C | |||
K | -100 to 1372°C | 0.1°C | -100 to 0°C : 1.2°C | ||
0 to 1372°C : 0.8°C | |||||
E | -50 to 1000°C | -50 to 0°C : 0.9°C | |||
0 to 1000°C : 1.5°C | |||||
J | -60 to 1200°C | -60 to 0°C : 1°C | |||
0 to 1200°C : 0.7°C | |||||
T | -100 to 400°C | -100 to 0°C : 1°C | |||
0 to 400°C : 0.7°C | |||||
N | -200 to 1300°C | -200 to 0°C : 1.5°C | |||
0 to 1300°C : 0.9°C | |||||
B | 600 to 1820°C | 1°C | 600 to 800°C : 2.2°C | ||
800 to 1000°C : 1.8°C | |||||
1000 to 1820°C : 1.4°C | |||||
RTD | Pt100 385 | -200 to 800°C | 0.1°C | -200 to 0°C : 0.5°C | By using Pt100-385 does not include lead resistance. |
0 to 400°C : 0.7°C | |||||
400 to 800°C : 0.8°C | |||||
Pt1000 385 | -200 to 630°C | -200 to 100°C : 0.3°C | |||
100 to 300°C : 0.5°C | |||||
300 to 630°C : 0.7°C | |||||
Pt200 385 | -200 to 630°C | -200 to 100°C : 0.8°C | |||
100 to 300°C : 0.9°C | |||||
300 to 630°C : 1.0°C | |||||
Pt500 385 | -200 to 630°C | -200 to 100°C : 0.4°C | |||
100 to 300°C : 0.5°C | |||||
300 to 630°C : 0.7°C | |||||
Cu10 | -100 to 260°C | 1.8°C | |||
Cu50 | -50 to 150°C | 0.7°C | |||
Switch | Close / open | Approx.. 1 mA test current. Short circuit display “Close Open” : OPEN Threshold value about 200 to 300Ω | |||
Continuity | 500Ω | <50Ω sound | Approx. 1 mA test current |
Output Functions (Simulation)
Functions | Reference | Ranges | Resolution | Accuracy | Remarks |
DC Voltage | 100 mV | -10 to 110 mV | 1 mV | 0.02 + 0.01 | Max output current 5 mA |
1 V | -0.1 to 1.10 V | 10 mV | 0.02 + 0.01 | Max output current 2 mA | |
10 V | -1 to 11 V | 0.1 mV | 0.02 + 0.01 | Max output current 5 mA | |
DC Current | 20 mA | 0 to 22 mA | 1 mA | 0.02 + 0.02 | External supply for simulate mA : 5V – 28V. Max. load 1KΩ at 20mA |
Resistance | 400Ω | 0 to 400Ω | 0.01Ω | 0.02 + 0.02 | Excitation current : ±0.5 – 3mA; if ±0.1 – 0.5 add 0.1Ω Accuracy does not include lead resistance |
4KΩ | 0 to 4KΩ | 0.1Ω | 0.05 + 0.025 | Excitation current : ±0.05 – 0.3mA; does not include lead resistance. | |
40KΩ | 0 to 40KΩ | 1Ω | 0.1 + 0.1 | Excitation current : ±0.01mA; does not include lead resistance. | |
Thermocouple | R | 0 to 1767°C | 1°C | 0 to 100°C:1.5°C | By using ITS-90 temperature scale, the accuracy does not include the error internal temperature compensation caused by a sensor. |
100 to 1767°C : 1.2°C | |||||
S | 0 to 1767°C | 0 to 100°C : 1.5°C | |||
100 to 1767°C : 1.2°C | |||||
K | -200 to 1372°C | -200 to -100°C : 0.6°C | |||
-100 to 400°C : 0.5°C | |||||
400 to 1200°C : 0.7°C | |||||
1200 to 1372°C : 0.9°C | |||||
E | -200 to 1000°C | -200 to -100°C : 0.6°C | |||
-100 to 600°C : 0.5°C | |||||
600 to 1000°C : 0.4°C | |||||
J | -200 to 1200°C | -200 to -100°C : 0.6°C | |||
-100 to 800°C : 0.5°C | |||||
800 to 1200°C : 0.7°C | |||||
T | -250 to 400°C | -250 to 400°C : 0.6°C | |||
N | -200 to 1300°C | -200 to -100°C : 1°C | |||
-100 to 900°C : 0.7°C | |||||
900 to 1300°C : 0.8°C | |||||
B | 600 to 1820°C | 400 to 800°C : 2°C | |||
800 to 1820°C : 1.1°C | |||||
RTD | Pt100 385 | -200 to 800°C | 0.1°C | -200 to 0°C : 0.3°C | By using Pt100-385 Excitation Current : ±0.5 to ±3 mA for Pt100, Cu10, Cu50; Excitation Current : ±0.05 to ±0.3mA for Pt200, Pt500, Pt1000; does not include lead resistance |
0 to 400°C : 0.5°C | |||||
400 to 800°C : 0.8°C | |||||
Pt200 385 | -200 to 630°C | -200 to 100°C : 0.8°C | |||
100 to 300°C : 0.9°C | |||||
300 to 630°C : 1.0°C | |||||
Pt500 385 | -200 to 630°C | -200 to 100°C : 0.4°C | |||
100 to 300°C : 0.5°C | |||||
300 to 630°C : 0.7°C | |||||
Pt1000 385 | -200 to 630°C | -200 to 100°C : 0.2°C | |||
100 to 300°C : 0.5°C | |||||
300 to 630°C : 0.7°C | |||||
Cu10 | -100 to 260°C | 1.8°C | |||
Cu50 | -50 to 150°C | 0.6°C | |||
Frequency | 100 Hz | 1 to 110 Hz | 0.01 Hz | ±2 count | Output voltage : +1 to 11 Vp-p (zero base waveform); Amplitude Accuracy : ±(5% +0.5V); Maximum load : >100KΩ; Duty cycle : 50% |
1 KHz | 0.100 to 1.100 KHz | 1 Hz | |||
10 KHz | 1 to 11 KHz | 0.1 KHz | |||
100 KHz | 10 to 110 KHz | 2 KHz | ±5 count | ||
Pulse | 100 Hz | 1 to 100000 cycles | 1 cycle | ±2 count | |
1 KHz | |||||
10 KHz | |||||
Switch | 100 Hz | 1 Hz to 110 Hz | 0.01 Hz | ±2 count | FET Switch maximum open/close Voltage : +28V Max. open/close Current : 50mA |
1 KHz | 0.100 KHz to 1.100 KHz | 1 Hz | |||
10 KHz | 1 KHz to 11 KHz | 0.1 KHz | |||
100 KHz | 10 KHz to 110 KHz | 2 KHz | ±5 count |
* Accuracy expressed as Percentage of Reading + Percentage of Range
- Multifunction Process Calibrator – Nagman 25
- 5V x 4 Nos. AAA Alkaline Batteries
- Operation Manual
- Test Leads
- Traceable Calibration Certificate
- Calibration Certificate from NABL Accredited – as per ISO/IEC 17025:2005 Laboratory