Input Functions (Measurement)
| Functions | Range | Resolution | Basic Accuracy |
| DC Voltage | ±1000V | 0.01mV | 0.1% |
| AC Voltage | 750V | 0.01mV | 0.5% |
| Resistance | 50MΩ | 0.1Ω | 0.1% |
| DC current | ±500mA | 1uA | 0.1% |
| AC current | 500mA | 1uA | 0.5% |
| Thermocouple | R, S, B, E, K, J, T, N | 1°C | 0.5% |
| RTD | Cu50, Pt100 | 1°C | 0.5% |
| CAP | 100mF | 0.01nF | 5% |
| Frequency | 10Hz ~ 100kHz | ||
| Diode test | √ | ||
| Continuity beeper | √ | ||
| Data hold | √ | ||
| Relative value measurement | √ | ||
Output Functions (Source)
| Functions | Range | Resolution | Basic Accuracy |
| DC Voltage | -10.00mV ~ 110.00mV -100.0mV ~ 1100.0mV -1.000V ~ 11.00V | 0.001mV, 0.01mV, 0.1mV | 0.2% |
| Resistance | 0 ~ 400.0Ω | 0.1Ω | 0.2% |
| DC Current | 33mA | 0.001mA | 0.2% |
| Simulating transmitter | √ | ||
| 25%, 100% Step output | √ | ||
| Automatic ramp | √ | ||
| Automatic step | √ | ||
| Display current and % of span | √ | ||
| Loop power | 24V | ||
| Frequency | 1.0Hz ~ 11.0kHz | ||
| Thermocouple | R, S, B, E, K, J, T, N | ||
| RTD | Cu50, Pt100 | ||
| Power Supply | 1.5V AA Alkaline battery |
| Auto Power-off | √ |
| Backlight | √ |
| Safety | CAT III 600V, Pollution degree 2 |
| Size | 206 × 97 × 60 |
| Weight | About 500g |
| Accessories | Test line, manual, fuse |
- Process Meter/Multimeter
- Test Leads & Fuse
- 1.5V ‘AA’ Alkaline Batteries (4 Nos.)
- Operation Manual
- Traceable Calibration Certificate
- Calibration Certificates are issued in Accordance with our Scope as granted by NABL per ISO/IEC 17025:2017 Standards