Portable/Benchtop
MTC 1200
- Advanced – Micro-controller based Technology
- Heavy Duty Portable / Bench-top Model
- High Accuracy, Resolution & Stability
- 128 x 64 Graphic Display
- Measurement Capability for TC, RTD, mV/mA/V & Resistance Signals
- Touch Membrane Keypad
- Switch Test Contact Measurement
- Interchangeable Single hole Thermowell Inserts
- Computer Interface & Calibration Software
- Precision Dry Block Calibrator with Interchangeable Thermowells
- Ideal for Steel, Glass, Metallurgical Industries, Cement Plants, Refineries, Fertilizer Plants, Thermal Power Stations etc.
- High Accuracy, Resolution & Stability with Measurement Capability for mV / V / mA, Resistance TC (ISA Types J, K, R, S, N, B, T), RTD (Pt100:IEC Standard) Signals
- Range: 300°C to 1200°C
- Resolution: 1°C
- Accuracy: ±2°C
- Stability: ±0.5°C
- Stabilisation Time: 15 Minutes
- Temperature Readout: °C / °F Selectable
- Well Diameter: 26 mm
- Immersion Depth: 105 mm
- Dry Block Material: Inconel
- Heating Time (Ambient to max.): 60 Minutes approx.
- Cooling Time (to min.): 45 Minutes approx. (with Forced Air Cooling) **
- Switch Test facility: Provided
- Thermowell Dia: 8 mm
- Housing / Mounting: Bench-top
- Power Supply: 230V AC, 50 Hz
- Instrument Dimensions (L x D x H): 160 x 365 x 450 mm
- Instrument Weight (approx.): 15 Kg.
- Measurement Capability: Thermocouples ISA Types J, K, R, S, N, B, T RTD Pt100 IEC Std.
mA 0 to 25 mA mV 0 to 100 / 1000 mV
Volt 0 to 10 V Resistance 0 to 500Ω / 3.5 KΩ
Measurement: Range, Resolution & Accuracy
Type | Range | Resolution | Accuracy | Type | Range | Resolution | Accuracy | |
mV (Low) | 0 to 100 | 0.01 | ±0.05% F.S. | TC Type J | -100 to 1200 | 0.1 | ±0.1% F.S. | |
mV (High) | 0 to 1000 | 0.1 | ±0.05% F.S. | TC Type K | -60 to 1260 | 0.1 | ±0.1% F.S. | |
Volts | 0 to 10 | 0.001 | ±0.05% F.S. | TC Type R | 150 to 1700 | 0.1 | ±0.1% F.S. | |
mA | 0 to 25 | 0.001 | ±0.05% F.S. | TC Type S | 170 to 1700 | 0.1 | ±0.1% F.S. | |
Ohms | 0 to 500 | 0.01 | ±0.05% F.S. | TC Type N | 0 to 1300 | 0.1 | ±0.1% F.S. | |
KOhms | 0 to 3.5 | 0.0001 | ±0.05% F.S. | TC Type B | 920 to 1820 | 0.1 | ±0.1% F.S. | |
RTD Pt100 | -100 to 800 | 0.1 | ±0.05% F.S. | TC Type T | 0 to 400 | 0.1 | ±0.1% F.S. |
- Basic Instrument
- Test Leads
- Mains Cable
- Thermowell of 8 mm Dia
- Tool for Insertion Tubes
- Spare Fuses
- 1/4” BSP (F) Hose Adaptor with 6 mm Hose (1.5 Meter Length)
- Computer Interface
- “MTCCal” Calibration Software
- Traceable Calibration Certificate
- Instruction Manual
- Carrying Case
- Additional Thermowells / Insertion Tubes : Single hole
- Calibration Certificates are issued in Accordance with our Scope as granted by NABL per ISO/IEC 17025:2017 Standards